TYPE 1

SMALL APPLIANCE

PRACTICE TEST 2

ARE YOU READY?

LET’S PRACTICE!

When using a passive system-dependent recovery method on an appliance with an operating compressor, you should run that appliances compressor
A passive system-dependent recovery device for small appliances
The sale of CFC and HCFC refrigerants is
Which of the refrigerants listed below should be recovered with current EPA-approved recovery devices?
When servicing a small appliance with a leak
For which of the following refrigeration systems/appliances would it be permissible to use a passive recovery device for refrigerant recovery?
When using any equipment or servicing any system that has schrader valves, it is critical to
If R-12 or R-22 are exposed to high temperatures from open flames, glowing hot metal surfaces etc, these refrigerants can decompose to form
When using a graduated charging cylinder, any refrigerant that is vented from the charging cylinder
A standard vacuum pump designed specifically for evacuation and dehydration can
The EPA section 608 certification must be renewed every
Prior to shipping any used refrigerant it is necessary to
A refrigerant that can be used as a direct service “drop-in” substitute for R-12 in a small appliance is
After installing and opening a piercing access valve, if the system is _______ do not begin the recovery procedure.
The EPA definition of a small appliance includes which of the following?
When using _________ , it is essential to take extra measures such as heating or striking the compressor, to help release trapped refrigerant from the compressor oil.
It is an EPA regulation that any person who opens an appliance for maintenance, service, or repair, must have at least one self-contained recovery machine available at their place of business. The only exception to this rule are persons working on
Which of the following are part of the EPA’s recommended safe work practices?
Recovery devices that were manufactured before November 15 1993 and are used for recovery of refrigerant from small appliances must be capable of
Piercing-type valves should only be used on which of the following type tubing materials?
When using a passive system-dependent recovery process, you should access both the high side and low side of the system for the refrigerant recovery if
On a small appliance with an operating compressor that has a completely plugged capillary tube, what is the minimum number of access valves that are needed to evacuate the refrigerant?
Technicians with a Type I small appliance certification are certified to recover refrigerant during the maintenance, service, or repair of
A recovery cylinder which is half full of recovered R-500 at normal room temperature, about 75F, in the absence of non-condensables, will be pressurized to
A refrigerant that can be used as a direct service “drop-in” substitue for R-22 in a small appliance is